Model NO.: YJV22 (copper) YJLV22 (aluminum)
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: XLPE
Brand: Ville
Trademark: VILLE
Transport Package: Wooden Case or as Per Requirement
Specification: iEC CE, ISO
Origin: Ningbo China
HS Code: 85
Model NO.: YJV22 (copper) YJLV22 (aluminum)
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, CE, RoHS, UL, VDE
Model: XLPE
Brand: Ville
Trademark: VILLE
Transport Package: Wooden Case or as Per Requirement
Specification: iEC CE, ISO
Origin: Ningbo China
HS Code: 85
XLPE/PVC/STA/PVC Armored Power Cable 0.6/1kV Code : YJV22 (copper) YJLV22 (aluminum)Standard : IEC 60502. GB/T 12706-2002
Construction : 1-Solid or Stranded Copper Conductor2-XLPE insulation (cross-linked PE). 3-PVC Inner Sheath 4  Steel Tape Armor 5-PVC outer sheath
Application :Preferably for installation indoors. in cable ducts and in industrial plants or switching stations. under ground installation with additional protection where mechanical damage is unexpected.Â
Technical Data : Max. operating temperature 90ºC Short circuit temperature 250ºCÂ
0.6/1kV, Single-core Steel Tape Armored power cable 0.6/1kV, 4-core Steel Tape Armored power cable
0.6/1kV, 2-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22
0.6/1kV, 3-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV,3+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV220.6/1kV, 3-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV,3+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4-core XLPE Insulated Steel Tape Armored PVC Sheathed power
/1kV, 5-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22Â
Nominal cross-section | OD. of conductor | Thickness of insulation | Thickness of sheath |
Approx. O.D. | Approx. weight | ||
kg/km | |||||||
mm 2 | mm | mm | mm | mm | CU | AL | |
5×4 | 2.2 | 1.0 | 1.8 | 16.0 | 439.7 | 315.5 | |
5×6 | 2.8 | 1.0 | 1.8 | 17.4 | 565.6 | 377 | |
5×10 | 4.1 | 1.0 | 1.8 | 20.9 | 839.8 | 519.2 | |
5×16 | 5.1 | 1.0 | 1.8 | 23.8 | 1180 | 671.1 | |
5×25 | 6.4 | 1.2 | 1.8 | 28.4 | 1749 | 943.5 | |
5×35 | 7.6 | 1.2 | 2.0 | 32.5 | 2318 | 1201 | |
5×50 | 8.3 | 1.4 | 2.1 | 36.4 | 3314 | 1841 | |
5×70 | 9.8 | 1.4 | 2.2 | 41.2 | 4414 | 2332 | |
5×95 | 11.5 | 1.6 | 2.4 | 46.2 | 5906 | 2953 | |
5×120 | 12.9 | 1.6 | 2.5 | 50.7 | 7271 | 3536 | |
5×150 | 14.5 | 1.8 | 2.7 | 56.5 | 9012 | 4317 | |
5×185 | 16 | 2.0 | 2.9 | 58.0 | 10436 | 4831 | |
5×240 | 18.3 | 2.2 | 3.1 | 69.2 | 13596 | 6258 | |
5×300 | 20.5 | 2.4 | 3.3 | 76.1 | 17049 | 7627 |
Nominal cross-section mm 2 | OD. of conductor mm  | Thickness of  insulation mm |
Thickness of outer sheath mm  | Approx.OD. mm   | Approx. weight kg/km | |||||
CUÂ | ALÂ | |||||||||
4×10+1×6 | 4.1 | 0.7 | 1.8 | 20.2 | 767.8 | 473.7 | ||||
2.8Â | 0.7Â | |||||||||
4×16+1×10 | 5.1 | 0.9 | 1.8 | 23.2 | 1092 | 621.1 | ||||
4.1Â | 0.7Â | Â | ||||||||
4×25+1×16 | 6.4 | 0.9 | 1.8 | 27.5 | 1611 | 864.3 | ||||
5.1Â | 0.7Â | Â | ||||||||
4×35+1×16 | 7.6 | 0.9 | 1.8 | 30.1 | 2012 | 1049 | ||||
5.1Â | 0.7Â | Â | ||||||||
4×50+1×25 | 8.3 | 1.0 | 2.0 | 34.9 | 2961 | 1627 | ||||
6.0Â | 0.9Â | Â | ||||||||
4×70+1×35 | 9.8 | 1.1 | 2.1 | 39.3 | 3941 | 2058 | ||||
7.0Â | 0.9Â | Â | ||||||||
4×95+1×50 | 11.5 | 1.1 | 2.3 | 44.2 | 5274 | 2614 | ||||
8.3Â | 1.0Â | Â | ||||||||
4×120+1×70 | 12.9 | 1.2 | 2.5 | 48.9 | 6596 | 3192 | ||||
9.8Â | 1.2Â | Â | ||||||||
4×150+1×70 | 14.5 | 1.4 | 2.6 | 53.4 | 7955 | 3782 | ||||
9.8Â | 1.1Â | |||||||||
4×185+1×95 | 16.0 | 1.6 | 2.8 | 58.9 | 9552 | 4477 | ||||
11.5Â | 1.1Â | Â | ||||||||
4×240+1×120 | 18.3 | 1.7 | 3.0 | 65.5 | 12157 | 5541 | ||||
12.9Â | 1.2Â | Â |
Code : YJV22 (copper) YJLV22 (aluminum)Standard : IEC 60502. GB/T 12706-2002
Construction : 1-Solid or Stranded Copper Conductor2-XLPE insulation (cross-linked PE). 3-PVC Inner Sheath 4  Steel Tape Armor 5-PVC outer sheath
Application :Preferably for installation indoors. in cable ducts and in industrial plants or switching stations. under ground installation with additional protection where mechanical damage is unexpected.Â
Technical Data : Max. operating temperature 90ºC Short circuit temperature 250ºCÂ
0.6/1kV, Single-core Steel Tape Armored power cable 0.6/1kV, 4-core Steel Tape Armored power cable
0.6/1kV, 2-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22
0.6/1kV, 3-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV,3+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV220.6/1kV, 3-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV,3+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4-core XLPE Insulated Steel Tape Armored PVC Sheathed power
/1kV, 5-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22 0.6/1kV, 4+1-core XLPE Insulated Steel Tape Armored PVC Sheathed power cable YJV22,YJLV22Â
Nominal cross-section | OD. of conductor | Thickness of insulation | Thickness of sheath |
Approx. O.D. | Approx. weight | ||
kg/km | |||||||
mm 2 | mm | mm | mm | mm | CU | AL | |
5×4 | 2.2 | 1.0 | 1.8 | 16.0 | 439.7 | 315.5 | |
5×6 | 2.8 | 1.0 | 1.8 | 17.4 | 565.6 | 377 | |
5×10 | 4.1 | 1.0 | 1.8 | 20.9 | 839.8 | 519.2 | |
5×16 | 5.1 | 1.0 | 1.8 | 23.8 | 1180 | 671.1 | |
5×25 | 6.4 | 1.2 | 1.8 | 28.4 | 1749 | 943.5 | |
5×35 | 7.6 | 1.2 | 2.0 | 32.5 | 2318 | 1201 | |
5×50 | 8.3 | 1.4 | 2.1 | 36.4 | 3314 | 1841 | |
5×70 | 9.8 | 1.4 | 2.2 | 41.2 | 4414 | 2332 | |
5×95 | 11.5 | 1.6 | 2.4 | 46.2 | 5906 | 2953 | |
5×120 | 12.9 | 1.6 | 2.5 | 50.7 | 7271 | 3536 | |
5×150 | 14.5 | 1.8 | 2.7 | 56.5 | 9012 | 4317 | |
5×185 | 16 | 2.0 | 2.9 | 58.0 | 10436 | 4831 | |
5×240 | 18.3 | 2.2 | 3.1 | 69.2 | 13596 | 6258 | |
5×300 | 20.5 | 2.4 | 3.3 | 76.1 | 17049 | 7627 |
Nominal cross-section mm 2 | OD. of conductor mm  | Thickness of  insulation mm |
Thickness of outer sheath mm  | Approx.OD. mm   | Approx. weight kg/km | |||||
CUÂ | ALÂ | |||||||||
4×10+1×6 | 4.1 | 0.7 | 1.8 | 20.2 | 767.8 | 473.7 | ||||
2.8Â | 0.7Â | |||||||||
4×16+1×10 | 5.1 | 0.9 | 1.8 | 23.2 | 1092 | 621.1 | ||||
4.1Â | 0.7Â | Â | ||||||||
4×25+1×16 | 6.4 | 0.9 | 1.8 | 27.5 | 1611 | 864.3 | ||||
5.1Â | 0.7Â | Â | ||||||||
4×35+1×16 | 7.6 | 0.9 | 1.8 | 30.1 | 2012 | 1049 | ||||
5.1Â | 0.7Â | Â | ||||||||
4×50+1×25 | 8.3 | 1.0 | 2.0 | 34.9 | 2961 | 1627 | ||||
6.0Â | 0.9Â | Â | ||||||||
4×70+1×35 | 9.8 | 1.1 | 2.1 | 39.3 | 3941 | 2058 | ||||
7.0Â | 0.9Â | Â | ||||||||
4×95+1×50 | 11.5 | 1.1 | 2.3 | 44.2 | 5274 | 2614 | ||||
8.3Â | 1.0Â | Â | ||||||||
4×120+1×70 | 12.9 | 1.2 | 2.5 | 48.9 | 6596 | 3192 | ||||
9.8Â | 1.2Â | Â | ||||||||
4×150+1×70 | 14.5 | 1.4 | 2.6 | 53.4 | 7955 | 3782 | ||||
9.8Â | 1.1Â | |||||||||
4×185+1×95 | 16.0 | 1.6 | 2.8 | 58.9 | 9552 | 4477 | ||||
11.5Â | 1.1Â | Â | ||||||||
4×240+1×120 | 18.3 | 1.7 | 3.0 | 65.5 | 12157 | 5541 | ||||
12.9Â | 1.2Â | Â |
Thermocouple Accessories,Thermocouple Components,Professional Thermocouple,Blind Flange
Thermocouple Wire,Thermocouple Connector Co., Ltd. , http://www.nbthermocouples.com