File column in the DS185XEVKIT software. Figure 1 shows the file column of the DS185x evaluation board (DS185XEVKIT) software. You can use the Gen Template and Fill Device buttons to set the device. The Gen Template button first generates a template for importing tables in Microsoft Excel or other formats. Using the Fill Device button, you can modify, save, or update the imported file.
Figure 1. The file field in the DS185XEVKIT software
Figure 2. Markers that may appear in the template file
Any line starting with ";" is a comment and can be ignored. The user can use the table not used for programming as a comment. The main device and Table 1 are annotated in the template file. When setting up the table, do not comment the table markers and register programming lines (ie, remove the ";" symbol at the beginning of the line).
The analysis program finds that there is no comment mark, and the text starts with the table number, confirming the start of a table. For example, when setting up Table 3, start by marking Table 3 (see Figure 2). After the table indicator, the analysis program starts looking for the special format data of the device internal setting table. As the template shows, the data should have the following format:
address | data | Annotation field |
The analysis program only pays attention to the address and data to determine whether the data conforms to the limits of a certain table. If the analysis program determines that the data does not meet the requirements of the table, it will report an error.
When the analysis program finds a non-data symbol or carriage return, it is considered that the setting of a certain table has been completed. Then, the analysis program starts looking for the beginning of a new table (corresponding to the indicator of the table), or the end of the file, and returns control to the main program. In the status window, the program reports the work that has been completed, and the work should be checked to confirm that no errors have occurred. Figure 3 shows the error code and the corresponding error.
Figure 3. When the input data does not meet the template parameters, the error code and the corresponding error
* Note that the x in the error code represents an actual table. Figure 4 lists the different tables and the corresponding x values.
Figure 4. Table corresponding to the value x
In the lookup table, even if only one value is modified, the user must set the entire table. Special bytes can be set for other configuration tables.
The order of the DS1856 table is different and is explained in the data sheet. The program generates a separate text file for the DS1856 and sets the table.
APM 40V DC Power Supply is usually used in testing cable or circuit breaker filed. To protect user`s device and the Laboratory Power Supply itself, protection functions of OVP,OCP,OPP etc. could be started according to the requirement.SCP function defaults to ON.
48Vdc Power Supply provides built-in standard automobile electrical testing curves,users can select any built-in curve to do the DUT performance test directly according to their demand.
Some features of the Power Supply as below:
- Ultrafast respond time and high efficiency
- Accurate voltage and current measurement capability
- Constant Power and wide range of voltage and current output
- Equips with LIST waveform editing function
- Master/Slave parallel and series operation mode for up to 10 units
- Voltage drop compensation by remote sense line.
- Compliant with SCPI communication protocol
- Support RS232/RS485/LAN/USB (standard) ,GPIB (optional)
- Have obtained CE,UL,CSA,FCC.ROHS
40V Dc Power Supply,Rack Mount Dc Power Supply,Lab Power Supply,Pc Power Supply
APM Technologies (Dongguan) Co., Ltd , https://www.apmpowersupply.com